Professional

Excel PC CV Dripline w/ Check Valve

Excel PC CV pressure compensating (PC) dripline, flexible, durable and precise with all the features you look for in a dripline.

Excel PC CV pressure compensating (PC) dripline is designed with floating diaphragms, built in with check valve, that regulate and maintain a consistent flow rate at variable inlet pressures in a wide range of demanding conditions. The dripline drip emitter’s check valve feature prevents water draining when water pressure drops below 2.5 PSI, protecting the drip line drip emitters from siphoning sediment, soil particles, and debris at the end of each irrigation cycle.

    Features
  • Can be installed above or below grade
  • The inline emitter check valves prevent drainage from the dripline when water pressure drops below 2.5 PSI, protecting the emitters against the siphoning of small sediment and soil particles into the drip emitter
  • Available in two flow rates, a wide range of spacing and drip tubing lengths to provide maximum design flexibility in a variety of applications
  • see more
  • The pressure compensating feature provides flow uniformity regardless of operating pressure and variation along the line
  • The drip emitter and the diaphragm are self-contained units molded to the interior wall of the tubing
  • Flow path design support superior clogging resistance
  • Turbulent flow through large labyrinth water passages leads water into the flow control chamber where a sensitive floating silicon diaphragm regulates and maintains a constant flow rate at variable inlet pressures. The self-flushing silicon diaphragm allows pressure to build up within the chamber and flush any debris not captured by the inlet filter.
  • Dripline includes one inlet and two outlets per each emitter
  • The intake inlet has a number of raised grooves that act as a secondary filter. The filter intake area is continuously flushed by water flow throughout the operation of the system, preventing particles from entering the labyrinth and giving the drip emitter its resistance to clogging.
  • The check valve and the dual, oppositely oriented directional outlets act as a physical barrier to root and debris intrusion
  • Resistant to chemicals and fertilizers commonly used in landscaping
  • Protected against UV degradation
  • Flexible tubing for easy installation
  • The dripline is printed with the flow rate and size for easy identification
  • Use with DIG 17 mm barb fittings, .670 OD compression fittings and universal Nut Lock™ fittings

technical


Excel PC CV Dripline w/ Check Valve
how to specify
Model Description
100' PC Dripline with CV
A1-112P-CV 12" spacing, 1 gph, .670 od
A1-118P-CV 18" spacing, 1 gph, .670 od
A5-112P-CV 12" spacing, .6 gph, .670 od
A5-118P-CV 18" spacing, .6 gph, .670 od
250' PC Dripline with CV
A5-218P-CV 18" spacing, .6 gph, .670 od
A5-224P-CV 24" spacing, .6 gph, .670 od
A1-212P-CV 12" spacing, 1 gph, .670 od
A1-218P-CV 18" spacing, 1 gph, .670 od
A1-224P-CV 24" spacing, 1 gph, .670 od
A5-212P-CV 12" spacing, .6 gph, .670 od
500' PC Dripline with CV
A1-524P-CV 24" spacing, 1 gPh, .670 od
A5-512P-CV 12" spacing, .6 gPh, .670 od
A5-518P-CV 18" spacing, .6 gPh, .670 od
A5-524P-CV 24" spacing, .6 gPh, .670 od
A1-512P-CV 12" spacing, 1 gPh, .670 od
A1-518P-CV 18" spacing, 1 gPh, .670 od
1000' PC Dripline with CV
A5-12P-CV 12" Spacing, .6 Gph, .670 Od
A5-18P-CV 18" Spacing, .6 Gph, .670 Od
A1-12P-CV 12" spacing, 1 gph, .670 od
A1-18P-CV 18" spacing, 1 gph, .670 od
A1-24P-CV 24" spacing, 1 gph, .670 od
    Specifications
  • Flow rates:
    • .6 GPH (2.3 L/H) color code - orange
    • 1 GPH (3.8 L/H) color code - gray
  • Operating pressure: 12-50 PSI (.8-3.5 BAR)
  • Check valve sealing pressure: 2.5 PSI (.17 BAR)
  • Check valve opening pressure: 4.3 PSI (.3 BAR)
  • Materials: Dow FINGERPRINT™DFDA-7510 NT linear low-density polyethylene resin with a minimum of 2% carbon black
  • Dripline color: brown
  • Size: 1/2 in. (.570 ID x .670 OD)(14.5 mm ID x 17 mm OD)
  • Spacing: 12 in., 18 in. or 24 in.(30.5 cm, 45.7 cm and 61 cm)
  • Available in 100 ft., 250 ft., 500 ft. and 1000 ft. coils (30 m, 75 m,150 m and 300 m)
  • Minimum bending radius: 1ft. (.3 m)
  • Filter requirement: minimum of 150 mesh
Maximum single lateral length Flow rate .6 GPH (2.3 L/H)
Dripper Spacing 15 PSI (1.0 BAR) 25 PSI (1.7 BAR) 35 PSI (2.4 BAR) 45 PSI (3.2 BAR)
12" (30 m) 215' (65 m) 304' (92 m) 343' (104 m) 442' (134 m)
18" (45 m) 244' (74 m) 406' (123 m) 459' (139 m) 548' (166 m)
24" (60 m) 370' (112 m) 482' (146 m) 617' (187 m) 772' (234 m)
Maximum single lateral length Flow rate 1.0 GPH (3.8 L/H)
Dripper Spacing 15 PSI (1.0 BAR) 25 PSI (1.7 BAR) 35 PSI (2.4 BAR) 45 PSI (3.2 BAR)
12" (30 m) 145' (44 m) 185' (56 m) 248' (75 m) 287' (87 m)
18" (45 m) 221' (67 m) 294' (89 m) 347' (105 m) 413' (125 m)
24" (60 m) 294' (89 m) 403' (122 m) 479' (145 m) 512' (155 m)
Flow rate per 100 feet (30 M) (Flow rate 0.6 GPH)
Dripper Spacing Flow (GPM) Flow (L/M) Flow (GPH) Flow (L/H)
12" (30 cm) 1.00 3.8 60 227
18" (45 cm) 0.67 2.5 40 151
24" (60 cm) 0.50 1.9 30 114
Flow rate per 100 feet (30 M) (Flow rate 1.0 GPH)
Dripper Spacing Flow (GPM) Flow (L/M) Flow (GPH) Flow (L/H)
12" (30 cm) 1.67 6.3 100 379
18" (45 cm) 1.11 4.2 66.7 252
24" (60 cm) 0.83 3.2 50 189





CAD details


CAD Files

CADdetailsLink
Click here to download DIG Corporation's high quality design files for your next project.

  • [+]   Excel™ .570 ID (17mm) Pressure Compensating Drip Line With Check Valve
  • 500ft-brownpoly-excel
    1 Remote Control Zone Assembly for Drip System P39-075 Thumb_dripzone-1 PDF DWG DXF
    2 Remote Control Zone Assembly for Drip System A53-075 Thumb_dripzone-2 PDF DWG DXF
    4 Excel™ drip line for subsurface installation, side view Thumb_c-4 PDF DWG DXF
    5 Excel™ drip line for subsurface installation, closed loop center feed layout Thumb_c-5 PDF DWG DXF
    6 Excel™ drip line for subsurface installation, side feed layout from a 1/2" riser Thumb_c-6 PDF DWG DXF
    7 Excel™ drip line for subsurface installation, closed loop, uneven shape center feed layout Thumb_c-7 PDF DWG DXF
    8 Excel™ line for subsurface installation, closed loop side feed layout from 1/2" riser (parking island) Thumb_c-8 PDF DWG DXF
    10 Vacuum relief valve layout for subsurface installation of drip line Thumb_c-10 PDF DWG DXF
    11 Flush valve layout for subsurface installation of drip line Thumb_c-11 PDF DWG DXF

asdfasfasdf


DIG_logo_white_web
Corporate Information

Where To Buy
About
Contact Us
Careers

Irrigation-Association-logo American-Society-of-irrigation-consultants-Logo American-Society-of-Landscape-Architects-Logo Recycling-logo

DIG Corporation
1210 Activity Drive
Vista, CA 92081 USA

Tel: (760) 727-0914
Fax: (760) 727-0282
Toll Free: (800) 322-9146


© copyright 2017 DIG Corporation water matters™ | All rights reserved